Solar PV Power Plant

Approximate Price, Size, Shadow Free Area Required and Time to implement a Solar PV Plant.
  • Residential
  • Rooftop Power Plant
  • Rs. 50~55/Watt
  • Solar Panel, Inverter, Structure, BOS, Design & Installation. Grid connected with no battery backup. (*restrictions apply)
  • 2.5 KW ~ 10 KW size
  • > 250~1000 Sq. Ft Roof
  • 2~4 Weeks Time
  • Call Us
  • Commercial
  • Rooftop or Ground
  • Rs. 35~40/Watt
  • Solar Panel, Inverter, Structure, BOS, Design & Installation. Grid connected with no battery backup. (* certain restrictions apply)
  • 10 KW ~ 250 KW Size
  • > 1000 ~ 25000 Sq. Ft. Shadow free Area
  • 1~3 Months Time
  • Let's Meet
  • Utility
  • Ground Mounted
  • Rs. 28~35/Watt
  • Solar Panel, Inverter, Structure, BOS, Design & Installation. Grid connected with no battery backup (* certain restrictions apply)
  • 250 KW ~ 5 MW Size
  • 1 Acre ~ 25 Acre Land
  • 3 ~ 18 Months Time
  • Let's Discuss
Enerzytech®
Powering the Energy Revolution

Thermal Power Plant: Electrical infrastructure, Plant Utilities, Equipment’s sizing calculations, Evaluation of data-sheets, Heat and mass balance calculations.

COMBINED CYCLE POWER PLANT (CCPP):
Feasibility Study, Basic & Detail Engineering, Layout Drawings, Process & Instrumentation Diagrams, Design calculations, Procurement assistance, Turnkey Solutions.

  • Extensive OEM experience for various General Electric (Frame 6B, 7EA, 7FA, 9E, and 9FA); Siemens, Mitsubishi, Alstom and Aero derivatives like LM6000, LM2500 Gas Turbine Generators up to 250 MW. 
  • Feasibility Study, Basic & Detail Engineering, Process & Instrumentation Diagrams, and Evaluation of data-sheets, Heat and mass balance calculations
    Procurement assistance, Turnkey Solutions for Electrical infrastructure and Plant Utilities for Combined Cycle Power Plant
  • Minor and major inspection of air-cooled and hydrogen cooled generators; Commissioning of various types of excitation systems.
  • Modelling & data analysis of various combined cycle configurations like single shaft, multi shaft and Thermal plant equipment - HRSGs, Aux boilers, Coal fired units, Steam Turbines, Condensers, Cooling Towers, Gas compressors, Chillers, Heat Exchangers, Major Fans, pumps etc.
  • Routine, Preventive and Emergency maintenance.
  • Design and implement Standard operating procedure (SOP) to meet any contingencies like grid collapse and black out
  • Repair or refurbishment of existing generators, replacement of AVR/Excitation system of any major component of Generators.
  • Generator modelling, Electrical & Mechanical stability of Generator, Grid Parallel operations & islanding

GENERATOR SERVICES

  • Rotor Services : Brushless exciter test, inspection and complete overhaul, Field ground detector troubleshooting for both RF and Optical systems, Retaining Ring removal & inspections, Non-destructive testing (NDT) of retaining rings, Collector ring machining, Complete rotor rewind, Post-rewind high speed balancing, Radial hydrogen seal replacement
  • Stator Services: End winding resonance detection and repairs “bump test”, Connection ring / parallel ring re-blocking & re-tying, End winding re-blocking & re-tying based on bump test & visual inspection results, End winding stiffening treatment, Corona and partial discharge activity abatement, Stator re-wedging, Flux probe installation, Dry ice “CO2” blasting excessively contaminated stators, High voltage bushing replacement, Temporary High voltage bushing & terminal plate leak repairs (“damming”), Replacement of stand-off insulators, Stator core iron repairs
  • Stator Testing: Insulation resistance & polarization index (“megger & P.I.”), DC Leakage test and Hi Pot, ELCID testing for core faults, Digital wedge mapping Ripple / PSDS spring depth gage testing for wedge tightness, DC resistance testing of each phase, Bump test / modal analysis of end windings & connection rings, Corona camera, Doble / Tan-Delta / Power Factor testing, Thermographic detection of high resistance connections
  • Westinghouse/MHI inner-cooled unit Testing: Transposition Testing, Tube to tube resistance test, Tube to copper resistance test, Core through bolt & building bolt torque checks & re-tightening, Megger of through bolts, Parallel ring flow testing, High voltage bushing replacement, Temporary High voltage bushing & terminal plate leak repairs (“damming”), Replacement of stand-off insulators, Stator core iron repairs,
  • Rotor Testing : Insulation resistance & polarization index (“megger & P.I.”), DC resistance testing, AC impedance test, Pole balance test, Recurring Surge Oscillography (RSO) test for shorted turns, Hydrogen seal pressure test for leaks, Borescope visual inspection,
  • Additional Capabilities : Consultant services, Root cause analysis

 

To know more about how your home or business can benefit from our products & services, Get in touch with us Today !

About Us

EnerzyTech® Industries Pvt. Ltd. is an emerging player in India's conventional and non-conventional energy sector and caters to utility, residential, commercial and Government clients. Our emphasis is on renewable energy, solar in particular.

Subscribe Here

Subscribe to our newsletter and stay updated on the latest developments and special offers!